{"id":4295,"date":"2025-11-17T09:32:26","date_gmt":"2025-11-17T09:32:26","guid":{"rendered":"https:\/\/automation-inside.com\/?p=4295"},"modified":"2025-12-09T09:55:29","modified_gmt":"2025-12-09T09:55:29","slug":"como-se-asigna-el-protocolo-de-interfaz-io-link-en-siemens-tia","status":"publish","type":"post","link":"https:\/\/we.automation-inside.com\/es\/como-se-asigna-el-protocolo-de-interfaz-io-link-en-siemens-tia\/","title":{"rendered":"\u00bfC\u00f3mo se asigna el protocolo de interfaz IO-Link en Siemens TIA?"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"4295\" class=\"elementor elementor-4295 elementor-2037\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f9bb731 e-flex e-con-boxed e-con e-parent\" data-id=\"f9bb731\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-6438a4a e-con-full e-flex e-con e-child\" data-id=\"6438a4a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9bea727 elementor-widget elementor-widget-global elementor-global-8176 elementor-global-10 elementor-widget-post-info\" data-id=\"9bea727\" data-element_type=\"widget\" data-widget_type=\"post-info.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-inline-items elementor-icon-list-items elementor-post-info\">\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-7119e78 elementor-inline-item\" itemprop=\"about\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-terms\">\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-post-info__terms-list\">\n\t\t\t\t<a href=\"https:\/\/we.automation-inside.com\/es\/tag\/control-tia\/\" class=\"elementor-post-info__terms-list-item\">Control TIA<\/a>, <a href=\"https:\/\/we.automation-inside.com\/es\/tag\/io-link\/\" class=\"elementor-post-info__terms-list-item\">IO-Link<\/a>, <a href=\"https:\/\/we.automation-inside.com\/es\/tag\/siemens-tia\/\" class=\"elementor-post-info__terms-list-item\">Siemens TIA<\/a>\t\t\t\t<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e658e6 elementor-widget elementor-widget-global elementor-global-7814 elementor-global-34 elementor-widget-theme-post-title\" data-id=\"3e658e6\" data-element_type=\"widget\" data-widget_type=\"theme-post-title.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">\u00bfC\u00f3mo se asigna el protocolo de interfaz IO-Link en Siemens TIA?<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7281d6d elementor-widget elementor-widget-text-editor\" data-id=\"7281d6d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h2>De la interfaz del sensor al controlador: c\u00f3mo asignar correctamente los datos<\/h2><p><em>Una pregunta frecuente sobre el terreno: \u00ab\u00bfC\u00f3mo reconozco qu\u00e9 datos env\u00eda mi sensor al controlador Siemens TIA a trav\u00e9s de IO-Link o Profinet, y d\u00f3nde llegan al controlador?\u00bb.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4bc879f elementor-widget elementor-widget-theme-post-featured-image elementor-widget-image\" data-id=\"4bc879f\" data-element_type=\"widget\" data-widget_type=\"theme-post-featured-image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1920\" height=\"1080\" src=\"https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/IO-Link-Systemarchitektur_GIF.webp\" class=\"attachment-full size-full wp-image-4296\" alt=\"Puedes ver sensores de los que salen cables negros que van a un master IO-Link en el centro. Un cable verde va de ah\u00ed al controlador.\" srcset=\"https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/IO-Link-Systemarchitektur_GIF.webp 1920w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/IO-Link-Systemarchitektur_GIF-300x169.webp 300w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/IO-Link-Systemarchitektur_GIF-1024x576.webp 1024w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/IO-Link-Systemarchitektur_GIF-768x432.webp 768w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/IO-Link-Systemarchitektur_GIF-1536x864.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">La arquitectura del sistema IO-Link permite la comunicaci\u00f3n bidireccional entre sensores, actuadores y la unidad de control, que act\u00faa como unidad de c\u00e1lculo del sistema global.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-19c3e4e elementor-widget elementor-widget-text-editor\" data-id=\"19c3e4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Al integrar sensores wenglor con IO-Link o Profinet en un controlador TIA de Siemens, es importante saber qu\u00e9 datos env\u00eda el sensor y d\u00f3nde llegan al controlador. El protocolo de interfaz sirve aqu\u00ed de base: muestra la asignaci\u00f3n exacta de los datos transmitidos: del protocolo de interfaz del sensor a las direcciones TIA en el controlador. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a01852 elementor-widget elementor-widget-text-editor\" data-id=\"1a01852\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h2>Por qu\u00e9 es tan importante el protocolo de interfaz<\/h2><p>El protocolo de interfaz muestra de forma transparente qu\u00e9 bytes y bits transmite el sensor y el significado de esta informaci\u00f3n: por ejemplo, valores de medici\u00f3n, informaci\u00f3n de estado o datos de diagn\u00f3stico.<\/p><p>S\u00f3lo si se conoce esta estructura, los valores recibidos pueden interpretarse correctamente en el sistema de control, leerse y utilizarse para otras tareas de automatizaci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17cae6c elementor-widget elementor-widget-text-editor\" data-id=\"17cae6c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h2>Ejemplo: protocolo de interfaz Profinet de un sensor de distancia l\u00e1ser<\/h2><p>El ejemplo de un sensor de distancia con triangulaci\u00f3n l\u00e1ser P3PC ilustra c\u00f3mo funciona esta asignaci\u00f3n. La estructura de datos puede dividirse en tres niveles: <\/p><ul><li>Protocolo del sensor (abajo a la izquierda): Muestra la asignaci\u00f3n de bits y bytes que transmite el sensor. Aqu\u00ed puedes ver qu\u00e9 informaci\u00f3n contiene cada \u00e1rea de datos. <\/li><li>controlador TIA (abajo a la derecha): En el entorno TIA de Siemens, estos datos se asignan a direcciones y variables espec\u00edficas, por ejemplo, como valores booleanos, enteros o reales.<\/li><li>Visi\u00f3n general (arriba): Ilustra el flujo de datos completo: desde el sensor hasta el protocolo de comunicaci\u00f3n y el nivel de aplicaci\u00f3n en el controlador.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2374b7c elementor-widget elementor-widget-text-editor\" data-id=\"2374b7c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<figure id=\"attachment_2040\" aria-describedby=\"caption-attachment-2040\" style=\"width: 800px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"wp-image-2040 size-large\" src=\"https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/10\/TIA_P3PC-1024x629.jpg\" alt=\"En la imagen se pueden ver tres tablas, que muestran el protocolo del sensor, la interfaz de control de la TIA y una visi\u00f3n general del flujo de datos.\" width=\"800\" height=\"491\" srcset=\"https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/10\/TIA_P3PC-1024x629.jpg 1024w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/10\/TIA_P3PC-300x184.jpg 300w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/10\/TIA_P3PC-768x471.jpg 768w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/10\/TIA_P3PC.jpg 1155w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption id=\"caption-attachment-2040\" class=\"wp-caption-text\">Ejemplo de protocolo de interfaz Profinet de un sensor l\u00e1ser de distancia.<\/figcaption><\/figure>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6bc2cd4 elementor-widget elementor-widget-global elementor-global-7853 elementor-global-22 elementor-widget-spacer\" data-id=\"6bc2cd4\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb2f108 elementor-widget elementor-widget-text-editor\" data-id=\"bb2f108\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h2>El resultado: estructuras de datos claras e integraci\u00f3n sencilla<\/h2><p>Con el protocolo de interfaz, la comunicaci\u00f3n entre el sensor y el controlador puede rastrearse de forma transparente. Esto permite asignar valores de medici\u00f3n de forma fiable, realizar diagn\u00f3sticos con mayor rapidez y automatizar procesos con mayor eficacia. <\/p><p>Tanto en la puesta en marcha de nuevos sistemas como en la optimizaci\u00f3n de los existentes, comprender la asignaci\u00f3n de los datos del proceso es la clave para una integraci\u00f3n de sensores fiable y de alto rendimiento.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-170e228 e-con-full elementor-hidden-mobile elementor-hidden-tablet e-flex e-con e-child\" data-id=\"170e228\" data-element_type=\"container\" data-settings=\"{&quot;sticky&quot;:&quot;top&quot;,&quot;sticky_on&quot;:[&quot;desktop&quot;,&quot;tablet&quot;],&quot;sticky_parent&quot;:&quot;yes&quot;,&quot;sticky_offset&quot;:0,&quot;sticky_effects_offset&quot;:0,&quot;sticky_anchor_link_offset&quot;:0}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9577fc8 elementor-grid-1 elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-posts--thumbnail-top elementor-widget elementor-widget-posts\" data-id=\"9577fc8\" data-element_type=\"widget\" data-settings=\"{&quot;classic_columns&quot;:&quot;1&quot;,&quot;classic_columns_tablet&quot;:&quot;2&quot;,&quot;classic_columns_mobile&quot;:&quot;1&quot;,&quot;classic_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:35,&quot;sizes&quot;:[]},&quot;classic_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;classic_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"posts.classic\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-classic elementor-grid\" role=\"list\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-24159 post type-post status-publish format-standard has-post-thumbnail hentry category-conceptos-basicos tag-control-del-nivel-de-llenado tag-leveltech tag-medicion-del-nivel-de-llenado tag-sensor-laser-de-distancia tag-sensor-retro-reflex tag-sensores-de-anillo-inductivo tag-sensores-de-distancia-por-ultrasonido\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/we.automation-inside.com\/es\/como-se-puede-medir-el-nivel-de-relleno-de-forma-fiable-independientemente-del-material-y-el-medio\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img decoding=\"async\" width=\"300\" height=\"169\" src=\"https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/Fuellstandsmessung_Headerbild_Neu-300x169.jpg\" class=\"attachment-medium size-medium wp-image-24160\" alt=\"Medici\u00f3n precisa de los niveles de relleno: sin contacto y fiable\" srcset=\"https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/Fuellstandsmessung_Headerbild_Neu-300x169.jpg 300w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/Fuellstandsmessung_Headerbild_Neu-1024x576.jpg 1024w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/Fuellstandsmessung_Headerbild_Neu-768x432.jpg 768w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/Fuellstandsmessung_Headerbild_Neu-1536x864.jpg 1536w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/11\/Fuellstandsmessung_Headerbild_Neu.jpg 1920w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/we.automation-inside.com\/es\/como-se-puede-medir-el-nivel-de-relleno-de-forma-fiable-independientemente-del-material-y-el-medio\/\" >\n\t\t\t\t\u00bfC\u00f3mo se puede medir el nivel de relleno de forma fiable, independientemente del material y el medio?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-date\">\n\t\t\tabril 23, 2026\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/we.automation-inside.com\/es\/como-se-puede-medir-el-nivel-de-relleno-de-forma-fiable-independientemente-del-material-y-el-medio\/\" aria-label=\"M\u00e1s informaci\u00f3n sobre \u00bfC\u00f3mo se puede medir el nivel de relleno de forma fiable, independientemente del material y el medio?\" tabindex=\"-1\" >\n\t\t\tAl art\u00edculo\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-24887 post type-post status-publish format-standard has-post-thumbnail hentry category-aplicacion tag-ingenieria-del-automovil tag-lectura-del-codigo tag-smart-camera-b60\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/we.automation-inside.com\/es\/como-pueden-los-codigos-en-los-paneles-de-control-leerse-de-forma-fiable-desde-una-larga-distancia\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"169\" src=\"https:\/\/we.automation-inside.com\/wp-content\/uploads\/2026\/04\/Armaturenbrett_Auto-300x169.jpg\" class=\"attachment-medium size-medium wp-image-24888\" alt=\"Salpicadero de un coche con etiquetas de c\u00f3digo pegadas\" srcset=\"https:\/\/we.automation-inside.com\/wp-content\/uploads\/2026\/04\/Armaturenbrett_Auto-300x169.jpg 300w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2026\/04\/Armaturenbrett_Auto-1024x576.jpg 1024w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2026\/04\/Armaturenbrett_Auto-768x432.jpg 768w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2026\/04\/Armaturenbrett_Auto-1536x864.jpg 1536w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2026\/04\/Armaturenbrett_Auto.jpg 1920w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/we.automation-inside.com\/es\/como-pueden-los-codigos-en-los-paneles-de-control-leerse-de-forma-fiable-desde-una-larga-distancia\/\" >\n\t\t\t\t\u00bfC\u00f3mo pueden los c\u00f3digos en los paneles de control leerse de forma fiable desde una larga distancia?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-date\">\n\t\t\tabril 17, 2026\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/we.automation-inside.com\/es\/como-pueden-los-codigos-en-los-paneles-de-control-leerse-de-forma-fiable-desde-una-larga-distancia\/\" aria-label=\"M\u00e1s informaci\u00f3n sobre \u00bfC\u00f3mo pueden los c\u00f3digos en los paneles de control leerse de forma fiable desde una larga distancia?\" tabindex=\"-1\" >\n\t\t\tAl art\u00edculo\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-24872 post type-post status-publish format-standard has-post-thumbnail hentry category-aplicacion tag-deteccion-de-objeto tag-prueba-de-documentos tag-rodamientos-de-alta-velocidad tag-superficies-oscuras\" role=\"listitem\">\n\t\t\t\t<a class=\"elementor-post__thumbnail__link\" href=\"https:\/\/we.automation-inside.com\/es\/como-se-puede-detectar-de-forma-fiable-la-ocupacion-de-compartimentos-de-estanteria-para-objetos-brillantes-y-negros\/\" tabindex=\"-1\" >\n\t\t\t<div class=\"elementor-post__thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"262\" height=\"300\" src=\"https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/09\/AdobeStock_50981877-262x300.jpeg\" class=\"attachment-medium size-medium wp-image-19506\" alt=\"\" srcset=\"https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/09\/AdobeStock_50981877-262x300.jpeg 262w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/09\/AdobeStock_50981877-895x1024.jpeg 895w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/09\/AdobeStock_50981877-768x878.jpeg 768w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/09\/AdobeStock_50981877-1343x1536.jpeg 1343w, https:\/\/we.automation-inside.com\/wp-content\/uploads\/2025\/09\/AdobeStock_50981877-1791x2048.jpeg 1791w\" sizes=\"(max-width: 262px) 100vw, 262px\" \/><\/div>\n\t\t<\/a>\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/we.automation-inside.com\/es\/como-se-puede-detectar-de-forma-fiable-la-ocupacion-de-compartimentos-de-estanteria-para-objetos-brillantes-y-negros\/\" >\n\t\t\t\t\u00bfC\u00f3mo se puede detectar de forma fiable la ocupaci\u00f3n de compartimentos de estanter\u00eda para objetos brillantes y negros?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-date\">\n\t\t\tabril 16, 2026\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/we.automation-inside.com\/es\/como-se-puede-detectar-de-forma-fiable-la-ocupacion-de-compartimentos-de-estanteria-para-objetos-brillantes-y-negros\/\" aria-label=\"M\u00e1s informaci\u00f3n sobre \u00bfC\u00f3mo se puede detectar de forma fiable la ocupaci\u00f3n de compartimentos de estanter\u00eda para objetos brillantes y negros?\" tabindex=\"-1\" >\n\t\t\tAl art\u00edculo\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3f13fdf e-con-full elementor-hidden-mobile e-flex e-con e-child\" data-id=\"3f13fdf\" data-element_type=\"container\" data-settings=\"{&quot;sticky&quot;:&quot;top&quot;,&quot;sticky_on&quot;:[&quot;desktop&quot;,&quot;tablet&quot;],&quot;sticky_parent&quot;:&quot;yes&quot;,&quot;sticky_offset&quot;:0,&quot;sticky_effects_offset&quot;:0,&quot;sticky_anchor_link_offset&quot;:0}\">\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Aprende a asignar correctamente el protocolo de interfaz IO-Link o Profinet en Siemens TIA. Paso a paso hacia una estructura de datos transparente entre el sensor y el controlador. <\/p>\n","protected":false},"author":7,"featured_media":4296,"comment_status":"closed","ping_status":"open","sticky":false,"template":"elementor_header_footer","format":"standard","meta":{"footnotes":""},"categories":[980],"tags":[1046,981,1047],"class_list":["post-4295","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-los-clientes-preguntan","tag-control-tia","tag-io-link","tag-siemens-tia"],"_links":{"self":[{"href":"https:\/\/we.automation-inside.com\/es\/wp-json\/wp\/v2\/posts\/4295","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/we.automation-inside.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/we.automation-inside.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/we.automation-inside.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/we.automation-inside.com\/es\/wp-json\/wp\/v2\/comments?post=4295"}],"version-history":[{"count":2,"href":"https:\/\/we.automation-inside.com\/es\/wp-json\/wp\/v2\/posts\/4295\/revisions"}],"predecessor-version":[{"id":15553,"href":"https:\/\/we.automation-inside.com\/es\/wp-json\/wp\/v2\/posts\/4295\/revisions\/15553"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/we.automation-inside.com\/es\/wp-json\/wp\/v2\/media\/4296"}],"wp:attachment":[{"href":"https:\/\/we.automation-inside.com\/es\/wp-json\/wp\/v2\/media?parent=4295"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/we.automation-inside.com\/es\/wp-json\/wp\/v2\/categories?post=4295"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/we.automation-inside.com\/es\/wp-json\/wp\/v2\/tags?post=4295"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}